Bus-Bar Connector for Rmu's & Gis

Bus-Bar Connector for Rmu's & Gis

2000.0 INR/Piece

Product Details:

  • Feature High mechanical strength, corrosion resistance, easy installation
  • Coating Type Electroplated Tin or Silver
  • Thermal Conductivity 390 W/mK
  • Density 8.96 Gram per cubic centimeter(g/cm3)
  • Installation Guideline Ensure clean, flat bus-bar surfaces before installation. Use appropriate torque for tightening bolts.
  • Surface Treatment Tin Plated / Silver Plated / Bare
  • Layer Single layer
  • Click to View more
X

Bus-Bar Connector for Rmu's & Gis Price And Quantity

  • 2000.0 INR/Piece
  • 500 Piece

Bus-Bar Connector for Rmu's & Gis Product Specifications

  • Connecting bus-bars within RMUs (Ring Main Units) & GIS (Gas Insulated Switchgear)
  • Single layer
  • Standard & Custom sizes available
  • 10 mm
  • 200 MPa
  • Tin Plated / Silver Plated / Bare
  • > 60kV
  • Bus-bar Connector for RMUs & GIS
  • Ensure clean, flat bus-bar surfaces before installation. Use appropriate torque for tightening bolts.
  • 60 mm
  • Electrolytic Copper / Aluminum Alloy
  • 105C
  • 390 W/mK
  • High mechanical strength, corrosion resistance, easy installation
  • Electroplated Tin or Silver
  • 8.96 Gram per cubic centimeter(g/cm3)
  • 24kV
  • 390 W/mK
  • Copper / Silver
  • Indoor / Outdoor (under enclosure)
  • Individually packed with protective cover
  • High, due to protective surface coating
  • Bolt-on mounting
  • Specified per bus-bar size
  • < 50
  • > 1000 M
  • Up to 1250A
  • IEC 62271-200, ISO 9001:2015
  • Self-extinguishing insulation available as option

Bus-Bar Connector for Rmu's & Gis Trade Information

  • 1000 Piece Per Day
  • 1-15 Days

Product Description

BusBar connector For RMUSGIS

The BusBar connector For RMUS GIS are widely applicable for the combined connection of Ring Main Units RMU  Gas Insulated Switchgear GIS mainly by the Tjoint  CrossConnector to supply more branches for expansion which electrically insulate and mechanically seal the connecting busbar and switchgear A bus bar is designed to make a solid connection point from one source to many branch circuits The offered BusBar connector For RMUSGIS is very efficient and safe for use




Superior Electrical and Mechanical Performance

Designed for both Ring Main Units RMUs and Gas Insulated Switchgear GIS our connectors feature high current carrying capacity and low contact resistance ensuring stable power distribution The robust construction and surface treatment optionstinplated silverplated or bareoffer enhanced corrosion resistance and longterm reliability in diverse environments


Easy Installation and Standard Compliance

These connectors come with bolton mounting for straightforward installation Installers are advised to ensure clean and flat busbar surfaces and use the specified torque for optimal performance Our products comply with IEC 62271200 and are manufactured under ISO 90012015 quality management assuring safety and consistency every time


Flexible Application and Customization

Available in both standard and custom sizes the connectors are suitable for varied RMU and GIS layouts Selfextinguishing insulation is available as an option for added safety With individually protectivepacked units you receive each connector in pristine conditionready for direct integration into your distribution setup

FAQs of Busbar Connector for RMUs  GIS

Q How should I install the busbar connector for maximum performance
A Ensure all busbar surfaces are thoroughly cleaned and flattened before installation Use the correct torque according to the busbar size to achieve secure lowresistance connections Bolton mounting makes the process straightforward for both standard and custom units

Q What standards do these busbar connectors comply with
A Our connectors meet IEC 62271200 for mediumvoltage switchgear and ISO 90012015 for quality management ensuring high performance for RMU and GIS applications

Q When is selfextinguishing insulation recommended for use
A Selfextinguishing insulation is advisable where enhanced fire safety is a priority such as in installations with higher risk of flame exposure or where regulatory standards require additional fire protection

Q Where can these busbar connectors be used
A They are designed for both indoor and outdoor installations provided the connectors are housed under enclosures to protect against direct weather exposure Ideal for use in RMUs and GIS systems

Q What are the material and surface finishing options available
A You can choose from electrolytic copper or aluminum alloy with surface treatments of tinplating silverplating or a bare finish Each option offers specific benefits in conductivity corrosion resistance and compatibility

Q How does the connector ensure longterm durability
A The connectors use a highly protective surface coating to resist corrosion maintain low contact resistance 50  and withstand mechanical and environmental stresses High tensile strength  200 MPa and a maximum operating temperature of 105C further support longterm reliability

Tell us about your requirement